April 2014 PLT-01067, Version: A.3
Page 7-7 Reader Configuration
The options on the Data Fields window determine the data manipulation operations performed by the
encoder prior to reporting the data to the access control system.
The data read from the card can be split into multiple fields, each with its own conversion operation.
6. Click the Add Field button.
7. A new field row will be listed. Each field has the following options:
Field Description
Field
Names the Data Field and is auto-incremented when selecting the Add Field
button. It is recommended this name be left at its default setting.
Data Type
Determines how the encoder is to interpret and convert the data in the field.
The following options are supported in the encoder:
Raw Data - no conversion
Binary Hex / Integer
BCD Nibble
BCD Byte
ASCII Decimal
ABA Track II as String
Start
Specifies the starting bit number in the data field. Combined with the Card
Data Length field (specified in bits), it defines the actual data in the data field
that is to be manipulated and reported to the access control system. This is
not the same as the Data Offset parameter set on the previous page.
Range 0-7FFF, default value of 0.
Card Data Length
See description above (Start).
Range 0-7FFF, default value of 0.
Data Representation
Allows the reversal of the order of bytes before applying the conversion
specified in the Data Type field.
Options are: None, and ByteReversed.